Cesium – Demineralized Water (DM Water)

Grade Industrial Grade
CAS Number 7732-18-5
Form Liquid
Purity >99 %
Chemical Formula H2O
pH value 6.5 to 7.5
Brand CESIUM
Chloride <1 mg/l
Specific conductivity 3mS/cm at 25 degree C
Total Hardness <1 mg/l
Iron <0.1 mg/l

Demineralized water that has undergone a deionization process to remove dissolved mineral ions and salts. Deionization typically involves passing water through ion exchange resins or membranes that selectively attract and remove charged particles, such as cations (positively charged ions) and anions (negatively charged ions).

The primary purpose of deionized water is to achieve a high level of purity by eliminating mineral content and other impurities.

AREA OF USE

Water for industrial cleaning applications
For rinsing components in machining industries
For chiller water circulation
For storage batteries
For dilution of coolants and in radiator application
For machinery requiring high-purity water as a coolant

FEATURES / ADVANTAGES

Low TDS
Low Electrical conductivity
Low presence of silica, sodium and other impurities
Suitable for various critical industrial processes
As per IS 1069:1993 standard for Storage batteries

SUGGESTED DILUTION

Ready to use solution

USAGE INSTRUCTIONS

For machinery usage or rinsing of components – Direct use in the bath

For coolant or storage batteries – Dilution as per manufacturer recommendation

SAFETY PRECAUTIONS

Do not drink or consume




Cesium - DI Water (Deionised) Water)

 

Grade Industrial Reagent Grade
CAS Number 7732-18-5
Form Liquid
Purity >99.99 %
Chemical Formula H2O
pH value 6 to 7.5
Brand CESIUM
Chloride <0.1mg/l
Specific conductivity < 2μs/cm at 25°C
Total Hardness NIL
Iron <0.1 mg/l

 

Deionized water, also referred to as demineralized water, is essentially the same as demineralized water. It is water that has undergone a deionization process to remove dissolved mineral ions and salts. Deionization typically involves passing water through ion exchange resins or membranes that selectively attract and remove charged particles, such as cations (positively charged ions) and anions (negatively charged ions).

The primary purpose of deionized water is to achieve a high level of purity by eliminating mineral content and other impurities.

AREA OF USE

Water for industrial cleaning applications
For rinsing components in machining industries
For chiller water circulation
For storage batteries
For dilution of coolants and in radiator application
For machinery requiring high-purity water as a coolant

FEATURES / ADVANTAGES

Low TDS
Low Electrical conductivity
Low presence of silica, sodium and other impurities
Suitable for various critical industrial processes
As per IS 1069:1993 standard for Storage batteries

COVERAGE

Not applicable

SUGGESTED DILUTION

Ready to use solution

USAGE INSTRUCTIONS

For machinery usage or rinsing of components – Direct use in the bath

For coolant or storage batteries – Dilution as per manufacturer recommendation

SAFETY PRECAUTIONS

Do not drink or consume
Keep away from children




Cesium- Distilled Water

CAS Number 7732-18-5
Form Liquid
Chemical Formula H2O
Total dissolved solids <0.1mg/l
Packing Type Can / Barrel
pH Value 6.5 to 7.5
Iron <0.1mg/l
Chloride <1mg/l
Specific conductivity 1μs/cm at 25°C

We offer high-purity Distilled water that is purified through our state-of-art water distillation plant. The water passes through two stage filtration, high-pressure Reverse Osmosis membranes and followed by single stage steam distillation, where the water is heated to reach boiling and form water vapour. The pure water vapour rises through the column, is condensed and collected in a clean vessel. The high-purity Distilled water is free of organic substances and minerals.
The water obtained through this process has extremely low TDS, electrical conductivity, silica, sodium and presence of other impurities. It is suitable for various laboratory applications, tissue culture labs, medical cleaning applications and to prepare reagents

AREA OF USE
To prepare buffers and reagents in laboratory
For preparation of media in biotech labs
For laboratory use as a standard solution
For cleaning of tissue culture lab apparatus
For medical cleaning applications
For critical processes with high sensitivity

FEATURES / ADVANTAGES
Low TDS
Low Electrical conductivity
Low presence of silica, sodium and other impurities
Free of organics and minerals
As per ASTM Type II water

SUGGESTED DILUTION
Ready to use solution

USAGE INSTRUCTIONS
Usage as per required application needs

SAFETY PRECAUTIONS
Do not drink or consume
Keep away from children




Cesium - Double Distilled Water

Usage / Application Industrial
CAS Number 7732-18-5
Form Liquid
Chemical Formula H2O
Brand  Cesium
Packing Type 5/10/20/35L Can

We offer high-purity Double Distilled water that is purified through our state-of-art water distillation plant. The water passes through two stage filtration, high-pressure Reverse Osmosis membranes and followed by single stage steam distillation, where the water is heated to reach boiling and form water vapour. The pure water vapour rises through the column, is condensed and collected in a clean vessel. This water is again distilled for a second time, to achieve double distillation. The high-purity Distilled water is free of organic substances and minerals.
The water obtained through this process has extremely low TDS, electrical conductivity, silica, sodium and presence of other impurities. It is suitable for various laboratory applications, tissue culture labs, medical cleaning applications and to prepare reagents.

AREA OF USE
To prepare buffers and reagents in laboratory
For preparation of media in biotech labs
For laboratory use as a standard solution
For cleaning of tissue culture lab apparatus
For medical cleaning applications
For critical processes with high sensitivityFEATURES / ADVANTAGES
Low TDS
Low Electrical conductivity
Low presence of silica, sodium and other impurities
Free of organics and minerals
As per ASTM Type II water

SUGGESTED DILUTION
Ready to use solution

USAGE INSTRUCTIONS
Usage as per required application needs